ARQVOLTGrid 50.01 HzDiscuss a Project

/

/

Energy Storage

■ 01 · Battery energy storage systems

Store it now.

Dispatch it when it counts.

Grid-scale and behind-the-meter battery systems from two to eight hours — sized to the connection, the market and the revenue case, and run by our energy management platform from day one.

2–8 h

Duration range

5 MWh

Typical block size

< 200 ms

Full-power response

20 yr

Design life

Figures illustrative

(01) Approach

A battery is only as valuable as the decisions it makes. We design the hardware and the software together, so every megawatt-hour is in the right place at the right price.

Battery storage systems and intelligent energy management. Every system is designed, built and operated by the same accountable team.

(02) Applications

Where it

creates value.

01

Energy arbitrage

Charge when power is cheap and plentiful, export at the evening peak.

02

Frequency response

Sub-second response that keeps the grid stable after a fault.

03

Renewable firming

Turn variable wind and solar output into firm, schedulable power.

04

Peak shaving

Cut demand charges and defer costly grid upgrades on industrial sites.

05

Backup & islanding

Keep critical load running through outages, automatically.

(03) How it works

From first study

to everyday operation.

01

Assess

Grid studies, revenue modelling and site constraints define the right size and duration.

02

Design

Block layout, power conversion, protection and controls engineered as one system.

03

Build

Factory-tested blocks installed and commissioned by one accountable team.

04

Operate

Remote dispatch, health monitoring and augmentation planning for twenty years.

Illustrative system · Single-line overview
Transmission networkGrid132 / 33 kVSubstationInverters · PCSPower conversionEMS · ControlsEnergy managementData center · IndustryDemand8 blocks · LFPBattery storageSoC 92%
Mode 01 / 03

Charge

When renewable output is high and prices are low, the site imports power through the substation and stores it in the battery blocks.

Grid · Substation · Power conversion · Storage · Energy management · DemandValues illustrative

(04) Technical information

Reference

specification.

Typical ranges for a reference system. Final specifications follow grid studies and site design.

Chemistry

Lithium iron phosphate (LFP)

Block energy

5 MWh per 20 ft enclosure

Duration

2, 4 or 8 hours

Round-trip efficiency

≈ 87% at point of connection

Grid connection

11 kV – 400 kV

Inverters

Grid-following or grid-forming

Thermal management

Liquid cooling, per-rack control

Fire safety

Gas detection, deflagration venting, water-based suppression

Illustrative reference values

(06) Questions

Good to know.

Other solutions:

Typically 12–18 months from final design to commercial operation, depending on the grid connection.

Yes. Sites are laid out with expansion bays so new blocks can be added without redesign.

We are vendor-neutral and select cells and enclosures per project, based on performance, warranty and supply chain.

Let’s build infrastructure

for what’s next.

Tell us about your site, your load or your grid connection. An engineer — not a sales team — will reply within two working days.

Let’s build infrastructure

for what’s next.

Tell us about your site, your load or your grid connection. An engineer — not a sales team — will reply within two working days.

Let’s build infrastructure

for what’s next.

Tell us about your site, your load or your grid connection. An engineer — not a sales team — will reply within two working days.